  Datasheet File OCR Text:
  type cdhc snap-in hybrid carboncap power ultracapacitors large cylindrical type the snap mount hybrid ultracapacitors are designed for board mountable power backup applications. the best applications for these type of ultracapacitors have low power, low energy, and low charge/discharge cycle rates. the main feature of these ultracapacitors is the ability to be rapidly charged preferably followed by a slow discharge. applications include solar lighting, led lighting, and portable devices. highlights - rapid charge - circuit board mountable - standard snap-in design specifcations operating temperature range storage temperature range C40 ?c to +60 ?c C40 ?c to +65 ?c rated voltage range 2.3 vdc, 2.50 vdc rated surge (do not discharge below 1 vdc) capacitance range 220 f to 1000 f capacitance tolerance C5% / +10% life at room temperature 10 years at rated voltage and 25 oc capacitance change 20% esr change 100% life test 1000 h @ rated voltage and +50 oc capacitance change 30% decrease esr change 100% increase cycle test >10,000 cycles (rated to half rated voltage at +25 c) capacitance change 20% decrease esr change 100% increase shelf life 1000 h without voltage at +60 c capacitance change 20% decrease esr change 100% increase rohs compliant ratings part number cdhc221k2r3sr cdhc301k2r3sr CDHC821K2R3SR cdhc102k2r3sr terminal confguration snap in snap in snap in snap in capacitance (f) (discharge w constant current at 25c) 220 300 820 1000 esr, dc (m), max 40 25 12 14 esr, ac @ 1khz (m), max 25 15 6 7 current - max peak (a) (1 s discharge rate to 50% of rated voltage) 26 41 87 77 leakage current (ma), max after 72 h at +25 c 0.20 0.55 0.50 0.70 usable power density, pd (kw/kg) (per iec 62391-2) 0.63 0.94 0.76 0.50 impedance match power, (kw/kg) 2.1 3.3 3.1 2.1 gravimetric energy density, emax (wh/kg) 5.2 6.6 7 5.2 energy available (wh) (at rated voltage) 0.13 0.18 0.49 0.60 weight (kg) 0.025 0.027 0.07 0.115 maximum continuous current (arms) (t=20c) 5 5.5 7.5 8 short circuit current (a) 92 153 383 329 cde cornell dubilier ? 1605 e. rodney french blvd. ? new bedford, ma 02744 ? phone: (508)996-8561 ? fax: (508)996-3830 obsolete
outline drawing and dimensions snap mount hybrid type part number dimensions (mm) d (+1/-0mm) l (2mm) cdhc221k2r3sr 22 45 cdhc301k2r3sr 22 45 CDHC821K2R3SR 27 80 cdhc102k2r3sr 35 88 cdhc 221 k 2r3 sr type capacitance tolerance voltage confguration (f) (%) (v) cdhc - carbon double layer 221 = 220 k = -5 /+10% 2r3 = 2.3 sr = snap-in, 2 pins hybrid cell part numbering system type cdhc snap-in hybrid carboncap power ultracapacitors large cylindrical type do not reverse polarity. 10.0 0.1 2 x 2.0 0.1 5.9 1.0 l d 10.0 negative terminal pc board mounting holes d c b a a b c d 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 the information contained in this drawing is the sole property of cornell dubilier electronics. any reproduction in part or as a whole without the written permission of cornell dubilier electronics is prohibited. dimensions are in mm tolerances: angular mach 1o bend 2o decimal 0.127mm finish checked comments: name title: size b dwg. no. rev scale: unless otherwise specified: p2 12/19/11 sheet 1 of 1 do not scale drawing rsc2r7xxsr paul jorissen date proprietary and confidential material drawn approval signatures ultra cap part must be free of dirt, foreign particles, oil, grease, dust, moisture, mold release, and packing material cde cornell dubilier ? 1605 e. rodney french blvd. ? new bedford, ma 02744 ? phone: (508)996-8561 ? fax: (508)996-3830 obsolete
notice and disclaimer: all product drawings, descriptions, specifcations, statements, information and data (collectively, the information) in this datasheet or other publication are subject to change. the customer is responsible for checking, confrming and verifying the extent to which the information contained in this datasheet or other publication is applicable to an order at the time the order is placed. all information given herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation or responsibility of any kind, expressed or implied. statements of suitability for certain applications are based on the knowledge that the cornell dubilier company providing such statements (cornell dubilier) has of operating conditions that such cornell dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty or representation regarding any such matter C and cornell dubilier specifcally and expressly disclaims any guarantee, warranty or representation concerning the suitability for a specifc customer application, use, storage, transportation, or operating environment. the information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. any technical advice inferred from this information or otherwise provided by cornell dubilier with reference to the use of any cornell dubilier products is given gratis (unless otherwise specifed by cornell dubilier), and cornell dubilier assumes no obligation or liability for the advice given or results obtained. although cornell dubilier strives to apply the most stringent quality and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures may still occur. accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be required. obsolete


▲Up To Search▲   

 
Price & Availability of CDHC821K2R3SR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X